Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
China Pharmacy ; (12): 1254-1257, 2017.
Article in Chinese | WPRIM | ID: wpr-514979

ABSTRACT

OBJECTIVE:To establish a method for simultaneous determination of 5 nucleoside from different parts of cultured Cordyceps militaris. METHODS:HPLC method was adopted. The determination was performed on InertSustain C18 column with mobile phase consisting of methanol-0.02 mol/L monobasic potassium phosphate solution (gradient elution) at the flow rate of 0.6 mL/min. The detection wavelength was set at 254 nm,the column temperature was 30 ℃. RESULTS:The linear ranges of uridine, inosine,guanosine,adenosine and cordycepin were 0.568-3.408 μg(r=0.9999),0.284-1.704 μg(r=0.9999),0.264-1.584 μg(r=0.9999),0.232-1.392 μg(r=0.9999)and 1.672-10.032 μg(r=0.9998),respectively. RSDs of precision,stability and repeatabili-ty tests were all lower than 3.0%. The recoveries were 98.2%-103.9%(RSD=1.97%,n=9),96.2%-101.6%(RSD=1.76%,n=9),96.7%-102.0%(RSD=1.94%,n=9),95.1%-99.4%(RSD=1.43%,n=9) and 95.6%-101.3%(RSD=1.82%,n=9). CON-CLUSIONS:The method is simple,precise,stable and repeatable,and can be used for simultaneous determination of 5 nucleoside from cultured C. militaris,the content of nucleosides are different in different parts of C. militaris.

2.
China Pharmacy ; (12): 1684-1686, 2017.
Article in Chinese | WPRIM | ID: wpr-514035

ABSTRACT

OBJECTIVE:To establish the method for the simultaneous determination of contents of 4 heavy metal elements in cultured Cordyceps militaris. METHODS:The samples were digested by nitric acid heating method and then determined by ICP-MS including radio-frequency power of 1.15 kW,sampling depth of 65 nm,auxiliary gas flow rate of 1.0 L/min,cooling gas flow of 13.0 L/min,temperature of 25 ℃,automatic plasma. RESULTS:The linear ranges of arsenic(As),cadmium(Cd),mer-cury (Hg) and lead (Pb) were 0-20 μg/mL(r=0.9970),0-10 μg/mL(r=0.9995),0-5 μg/mL(r=0.9955),0-20 μg/mL(r=0.9960),respectively. Detectio limit were 0.128,0.003,0.002,0.004 mg. RSDs of precision,stability and reproducibility tests were all lower than 6.5%. Recoveries of them were 90.4%-100.6%(RSD=3.45%,n=9),94.3%-101.3%(RSD=2.93%,n=9), 90.0%-102.3%(RSD=4.03%,n=9),92.3%-103.0%(RSD=3.53%,n=9),respectively. CONCLUSIONS:The method is sim-ple,precise,stable,reproducible,and can be used for simultaneous determination of contents of 4 heavy metal elements in cul-tured C. militaris. The contents of As,Cd,Hg and Pb in 10 batches of sample are all in line with related national standards.

SELECTION OF CITATIONS
SEARCH DETAIL